Multisim Ultiboard Circuit Design Suite PowerPro 12 0 1 Free Download Full Version
Multisim Ultiboard Circuit Design Suite PowerPro 12 0 1 Free Download Full Version

Multisim & Ultiboard (Circuit Design Suite) PowerPro 12.0.1
New version NI Circuit Design Suite Power Pro 12.0.1, includes the familiar products: NI Multisim schematic capture and simulation environment and NI Ultiboard layout and routing.
- NI Multisim Power Pro
NI Multisim software combines intuitive capture with powerful simulation to help you quickly, easily, and efficiently design and validate a circuit.
With Multisim, you can quickly build a schematic with a comprehensive component library and emulate circuit behavior using the industry-standard SPICE simulator.
This software provides an easy-to-use interface to SPICE, ensuring accurate and immediate simulation results that uncover flaws earlier in the design process and reduce prototype errors and time to market.
You can purchase Multisim as a complete, integrated design and test platform to seamlessly transfer schematics to layout in NI Ultiboard software and incorporate real-world measurements with the NI LabVIEW graphical programming environment.
- NI Ultiboard Power Pro
NI Ultiboard software provides an easy-to-use and intuitive platform to lay out and route a printed circuit board (PCB) design. With Ultiboard, you can complete the entire layout process, from part placement to copper routing, in a flexible design environment that optimizes speed and control. Automated processes, such as the integrated advanced autorouter, quickly define noncritical trace placement, while manual trace placement ensures the precise control to efficiently take a design to prototype.
Seamless integration with NI Multisim software optimizes the design experience, ensuring that you can easily transfer schematics to PCB design and effortlessly annotate changes between layout and capture. You can export a final design to industry-standard file formats, such as Gerber and DXF, to complete the integrated flow of design to prototype.
This new release brings with it a long list of quality improvements and new database parts. The following list is a summary of the whats included:
- Over 200 new and updated Analog Devices components
- Over 975 new and updated ON Semiconductor components
- Over 525 new Infineon MOSFETs, each with up to 3 levels of model complexity (Power Pro and Edu only)
- Over 50 new National Instruments connectors
- Over 50 new industry connectors, including RCA, HDMI, DVI, and JTAG headers
- Over 1,400 duplicate symbols have been removed
- Hierarchical and LabVIEW-Multisim Co-simulation Connector Improvements
- 150 Bug Fixes
Name: NI Circuit Design Suite Power Pro
Version: 12.0.1 (12.0.923)
Interface: English, Russian
OS: Windows XP / Vista / Seven / Server 2003 R2 / Windows Server 2008 R2
Size: 625.4 mb
Note: Circuit Design Suite 12.0.1 supports Windows XP 32bit edition, Windows Vista 32bit and 64bit editions, Windows 7 32bit and 64bit editions, Windows Server 2003 R2 (32bit) and Windows Server 2008 R2 (64bit). Circuit Design Suite 12.0.1 does not support Windows 2000/NT/Me/98/95, Windows XP 64bit edition, or the Windows Server non-R2 editions.
Click below button to download its torrent file

Available link for download
Friday, August 26, 2016
Official OS 7 1 0 523 for Porsche Design P9981 from XL Indonesia
Official OS 7 1 0 523 for Porsche Design P9981 from XL Indonesia
BlackBerry Handheld Software v7.1.0.1650 (All Languages)
Package Version: 7.1.0.1650
Consisting of:
Applications: 7.1.0.523
Software Platform: 5.1.0.398
File name: 9981jAllLang_PBr7.1.0_rel1650_PL5.1.0.398_A7.1.0.523_XL_Indonesia__Non_Vodafone_.exe
File size: 285.6MB
Download Here
Available link for download
Wednesday, August 24, 2016
Precision Water Management in Irrigation Systems Circuit Design
Precision Water Management in Irrigation Systems Circuit Design
The article presents a simple circuit idea which can be used for implementing an efficient water management and control in farms and irrigation systems.
The idea was requested by Mr. Ajinkya Sonwane, Mr. Akshay Kokane and Mr. Kunal Raut, studying in AISSMS IOIT College of Engineering.
The idea was requested by Mr. Ajinkya Sonwane, Mr. Akshay Kokane and Mr. Kunal Raut, studying in AISSMS IOIT College of Engineering.
As per the request, water needs to be controlled and managed at a given predetermined rate depending on the type of crop and its necessity.
The easiest possible solution to this could be in the form of solenoid timers which could be programmed once by the farmers for enabling an automatic water management, everyday, without any further intervention, until the crop or season changes. The timer is supposed to be extremely flexible, easy to operate and cost effective.
The idea here is to connect DC solenoids valves at different nodes of the distribution pipe network and control these solenoid valves using timers.
The timer controller unit could be positioned in a specific position (control room) for enabling the farmers to set the timing as per the needs anytime, as required, and the signals could be appropriately transmitted to the relevant valves through wires for executing the controlled release of water across the given area.
The following circuit idea using the IC 4060 may be considered perfectly suitable for the proposed precision water management in irrigation system.
The circuit functioning can be understood with the help of the following points:

The IC 4060 can be seen configured in its standard timer/oscillator mode.
Pin#10 and pin#9 are associated with the time delay setting for the output pinouts 3, 13, 14 and 15.
The SW1 switch facilitates the time delay selection through the respective resistors which decides for how long the output of the IC may be rendered active, ensuring that the connected solenoid valve stays switched ON and in a water supplying mode only during this period of time.
The indicated timing resistors for SW1 are arbitrarily arranged and must be appropriately calculated during the actual implementation as per the crop specifications, and water availability.
SW1 is specified for a 4 position selection which can be increased to more positions by simply using a switch with more number of contacts and by adding subsequent number of resistors in the appropriate order.
SW2 is also a rotary switch identical to SW1 and is positioned for selecting the switching mode of the solenoid valve.
Pin#3 provides a continuous ON mode for the valve for the selected time slot after which the valve is switched off until the next day, whereas pin13, 14, 15 provides an oscillating (ON/OFF/ON/OFF) activation mode for the solenoid so that the water is managed in a more controlled manner, however this may be optional if the valve nozzle is correctly dimensioned for a restricted flow as per the given criteria.
The whole system can be seen powered through a small solar panel which makes the entire system full automatic.
When dawn sets in, the solar panel voltage gradually rises and at a particular point reaches a 12V level activating the connected relay.
The relay contacts instantly connect the solar voltage with the circuit initializing the procedure wherein the IC pin#12 is reset by C2 forcing the IC to begin counting from zero.
All the outputs are rendered with a zero logic initially which makes sure that the TIP127 transistor commences with a switch ON condition and triggers the connected solenoid valve.
If SW2 is positioned with pin#3, the TIP127 and the valve stay switched ON continuously supplying water through the nozzle in a dripping manner until the set timing is elapsed and pin#3 becomes high.
As soon as pin#3 goes high the logic high instantly latches pin#11 of the IC and stops the IC from any further counting, freezing the procedure permanently for the day. The logic high is also transferred to the base of the TIP127 switching it OFF along with the valve system. The water supply to the crops at this moment gets halted.
At dusk when the sunlight weakens and gets below the relay holding level, the relay is switched OFF which also switches OFF the associated circuit stages, until the next day when the procedure undergoes the triggering of a fresh cycle.
PB1 is used for resetting the proceedings at anytime for enabling a new start for the circuit.
Many number of the above explained systems can be implemented at the specified nodes of the distribution pipe for achieving the desired precision water management in irrigation systems.
How to Calculate the Timing Resistors
The timing resistors associated with SW1 can be calculated with some experimentation as given below:
Any arbitrarily selected resistor may be initially switched with SW1, say for example we choose the 100k resistor as the reference.
Now switch ON the circuit to initiate the procedures, the red LED will be seen coming ON.
As soon as the circuit initiates monitor the timing using a stop watch or a clock and watch when the green LED turns ON switching OFF the red LED.
Note the timing achieved using the particular resistor which is 100K in this case.
Lets say it resulted in a delay period of 450 seconds, then taking this as the yardstick other values could be simply determined through a simple cross multiplication as given below:
100/R = 450/t
where R stands for the other unknown resistor value and "t" is the desired time delay for the solenoid valve.
The easiest possible solution to this could be in the form of solenoid timers which could be programmed once by the farmers for enabling an automatic water management, everyday, without any further intervention, until the crop or season changes. The timer is supposed to be extremely flexible, easy to operate and cost effective.
The idea here is to connect DC solenoids valves at different nodes of the distribution pipe network and control these solenoid valves using timers.
The timer controller unit could be positioned in a specific position (control room) for enabling the farmers to set the timing as per the needs anytime, as required, and the signals could be appropriately transmitted to the relevant valves through wires for executing the controlled release of water across the given area.
The following circuit idea using the IC 4060 may be considered perfectly suitable for the proposed precision water management in irrigation system.
The circuit functioning can be understood with the help of the following points:

The IC 4060 can be seen configured in its standard timer/oscillator mode.
Pin#10 and pin#9 are associated with the time delay setting for the output pinouts 3, 13, 14 and 15.
The SW1 switch facilitates the time delay selection through the respective resistors which decides for how long the output of the IC may be rendered active, ensuring that the connected solenoid valve stays switched ON and in a water supplying mode only during this period of time.
The indicated timing resistors for SW1 are arbitrarily arranged and must be appropriately calculated during the actual implementation as per the crop specifications, and water availability.
SW1 is specified for a 4 position selection which can be increased to more positions by simply using a switch with more number of contacts and by adding subsequent number of resistors in the appropriate order.
SW2 is also a rotary switch identical to SW1 and is positioned for selecting the switching mode of the solenoid valve.
Pin#3 provides a continuous ON mode for the valve for the selected time slot after which the valve is switched off until the next day, whereas pin13, 14, 15 provides an oscillating (ON/OFF/ON/OFF) activation mode for the solenoid so that the water is managed in a more controlled manner, however this may be optional if the valve nozzle is correctly dimensioned for a restricted flow as per the given criteria.
The whole system can be seen powered through a small solar panel which makes the entire system full automatic.
When dawn sets in, the solar panel voltage gradually rises and at a particular point reaches a 12V level activating the connected relay.
The relay contacts instantly connect the solar voltage with the circuit initializing the procedure wherein the IC pin#12 is reset by C2 forcing the IC to begin counting from zero.
All the outputs are rendered with a zero logic initially which makes sure that the TIP127 transistor commences with a switch ON condition and triggers the connected solenoid valve.
If SW2 is positioned with pin#3, the TIP127 and the valve stay switched ON continuously supplying water through the nozzle in a dripping manner until the set timing is elapsed and pin#3 becomes high.
As soon as pin#3 goes high the logic high instantly latches pin#11 of the IC and stops the IC from any further counting, freezing the procedure permanently for the day. The logic high is also transferred to the base of the TIP127 switching it OFF along with the valve system. The water supply to the crops at this moment gets halted.
At dusk when the sunlight weakens and gets below the relay holding level, the relay is switched OFF which also switches OFF the associated circuit stages, until the next day when the procedure undergoes the triggering of a fresh cycle.
PB1 is used for resetting the proceedings at anytime for enabling a new start for the circuit.
Many number of the above explained systems can be implemented at the specified nodes of the distribution pipe for achieving the desired precision water management in irrigation systems.
How to Calculate the Timing Resistors
The timing resistors associated with SW1 can be calculated with some experimentation as given below:
Any arbitrarily selected resistor may be initially switched with SW1, say for example we choose the 100k resistor as the reference.
Now switch ON the circuit to initiate the procedures, the red LED will be seen coming ON.
As soon as the circuit initiates monitor the timing using a stop watch or a clock and watch when the green LED turns ON switching OFF the red LED.
Note the timing achieved using the particular resistor which is 100K in this case.
Lets say it resulted in a delay period of 450 seconds, then taking this as the yardstick other values could be simply determined through a simple cross multiplication as given below:
100/R = 450/t
where R stands for the other unknown resistor value and "t" is the desired time delay for the solenoid valve.
Available link for download
Labels: